2. HOLDOFF DEBOUNCE option transmits messages
immediately upon change of switch condition, and will
also hold off a message of further change for the time
period of the selected debounce.
EXAMPLE: A Quick Talk is used as a gate doorbell. It is
practical for the message to be transmitted
immediately, and also desirable to have a
one-minute debounce before the same
message is re-sent, even if the button is
pushed repeatedly.
TO USE SWITCH 1 AS A NORMAL HOLDOFF
CONTACT CLOSURE:
a. Pick up the telephone receiver and listen for the
acknowledge tone.
b. Dial "5110" to suppress the phrase for Switch 1 OPEN,
and to prevent message transmission for the button
being pressed.
b. Select the code for the desired Holdoff time from Table 8
below.
c. Dial "813x", "x" being the selected code from Table 8,
below. A beep indicates the command is accepted.
NOTE: For the gate doorbell example above, dial
"8134" for 1-minute holdoff.
d. To complete the programming, dial "999", wait for the
beep, then hang up the telephone.
TO USE SWITCH 2 AS A NORMAL HOLDOFF
CONTACT CLOSURE:
a. Pick up the telephone receiver and listen for the
acknowledge tone.
b. Dial "5210" to suppress the phrase for Switch 2 OPEN,
and to prevent message transmission for the button
being pressed.
b. Select the code for the desired Holdoff time from Table 8
below.
c. Dial "823x", "x" being the selected code from Table 8,
below. A beep indicates the command is accepted.
d. To complete the programming, dial "999, wait for the
beep, then hang up the telephone.
4. SETTING DEBOUNCE OPTIONS
1. NORMAL DEBOUNCE is an option specifying that the
switch must remain in its changed condition for a user-
specified time period ("debounce"), before generating a
message for the changed condition.
EXAMPLE: A sensor is used to detect a car in a "No
Parking" zone. Since it is undesirable for a
message to be generated by normal traffic
through the "No Parking" zone, a five-minute
Normal Debounce is used. Only if the sensor
is activated for a full five minutes will the "car
illegally parked" message be transmitted.
TO USE SWITCH 1 AS A NORMAL DEBOUNCED
CONTACT CLOSURE:
a. Pick up the telephone receiver and listen for the ac-
knowledge tone.
b. Select the code for the desired Debounce time from
Table 7 below.
c. Dial "812x", "x" being the selected code from Table 7,
below. A beep indicates the command is accepted.
NOTE: For the "No Parking" zone example above,
dial "8126" for 5-minute debounce.
d. To complete the programming, dial "999", wait for the
beep, then hang up the telephone.
TO USE SWITCH 2 AS A NORMAL DEBOUNCED
CONTACT CLOSURE:
a. Pick up the telephone receiver and listen for the ac-
knowledge tone.
b. Select the code for the desired Debounce time from
Table 2, below.
c. Dial "822x", "x" being the selected code from Table 7,
below. A beep indicates the command is accepted.
d. To complete the programming, dial "999, wait for the
beep, then hang up the telephone.
There are two modes of contact debounce;
1. Normal Debounce, and 2. Holdoff Debounce:
-
DEF AULT
DEBOUNCE TIME CODE
NUMBER
No Debounce
.....................
1
10 seconds
........................
2
30 seconds
........................
3
1 minute
...........................
4
3 minutes
.........................
5
5 minutes
.........................
6
HOLDOFF TIME CODE
NUMBER
No Holdoff
.........................
1
10 seconds
........................
2
30 seconds
........................
3
1 minute
...........................
4
3 minutes
.........................
5
5 minutes
.........................
6
-
DEF AULT
TABLE 7
TABLE 8
Q
UICK
T
ALK
A
DV ANCED
F
EATURES